I-Kingflex Thermal Insulation Tubes ziyi-cell evaliweyo ye-elastomeric foam isakhiwo esine-non-porous composition inika ukusebenza kakuhle kwe-thermal kunye nokukhuselwa kwiingxaki ezisondeleyo ze-condensation kunye nokunceda ukufunxa isandi.Ngenxa yokuzinza kwabo kwe-dimensional, banciphisa ukukhuhla kwaye banciphise ixesha lokufakela kakhulu.

Ubunzima obuqhelekileyo bodonga lwe-1/4", 3/8", 1/2", 3/4",1", 1-1/4", 1-1/2" kunye no-2" (6, 9, 13, 19, 25, 32, 40 kunye ne-50mm).

Ubude obusemgangathweni kunye ne-6ft (1.83m) okanye i-6.2ft (2m).


Iinkcukacha zeMveliso

Iithegi zeMveliso

Inkcazo

I-Kingflex Thermal Insulation Tubes ayigcini nje ngokuhambelana nokusingqongileyo, ayinabungozi kwimpilo yabantu, ine-zero ye-Ozone Depletion Potential (ODP), i-Global Warming Potential (GWP) engaphantsi kwesihlanu, kunye ne-Volatile Organic Compound (VOC) ephantsi. ngaphantsi kwe-6 µg/m2/hr kwiiyure ezingama-24.Ukupheliswa kwe-chlorofluorocarbons (CFC) kunye ne-hydro chlorofluorocarbons (HCFC) kwinkqubo yokuvelisa ngelixa ithobela iimfuno ze-LEED yenza i-BOLNFLEX Thermal Insulation Tubes ilungele ukusetyenziswa kwiiprojekthi ezidinga umoya opholileyo, ifriji, imibhobho yamanzi abandayo, kunye nemibhobho yamanzi ashushu yokufakelwa kwe-thermal. .

Iphepha leDatha lobuGcisa

Kingflex Data yoBugcisa

Ipropati

Iyunithi

Ixabiso

Indlela yoVavanyo

Uluhlu lobushushu

°C

(-50 - 110)

GB/T 17794-1999

Uluhlu lokuxinana

Kg/m3

45-65Kg/m3

I-ASTM D1667

Ukufikeleleka komphunga wamanzi

Kg/(mspa)

≤0.91×10 ﹣¹³

DIN 52 615 BS 4370 Icandelo 2 1973

μ

-

≥10000

 

I-Thermal Conductivity

W/(mk)

≤0.030 (-20°C)

I-ASTM C 518

≤0.032 (0°C)

≤0.036 (40°C)

Ukukala koMlilo

-

Iklasi 0 kunye neKlasi yoku-1

BS 476 Icandelo 6 inxalenye yesi-7

I-Flame Spread and Smoke Developed Index

 

25/50

I-ASTM E84

Isalathiso seoksijini

 

≥36

GB/T 2406,ISO4589

Ukufunxwa kwamanzi,% ngokoMqulu

%

20%

I-ASTM C 209

Uzinzo lweDimension

 

≤5

I-ASTM C534

Ukuchasa iifungus

-

Kulungile

I-ASTM 21

Ukumelana ne-ozone

Kulungile

GB/T 7762-1987

Ukuchasa kwi-UV kunye nemozulu

Kulungile

I-ASTM G23

Izinto eziluncedo kwimveliso

Ukuphucula ukusebenza kakuhle kwamandla kwisakhiwo

Ukunciphisa ukuhanjiswa kwesandi sangaphandle ukuya ngaphakathi kwesakhiwo

Funxa izandi eziphindaphindayo ngaphakathi kwesakhiwo

Ukubonelela ngokusebenza kakuhle kwe-thermal

Gcina isakhiwo sishushu ebusika kwaye sipholile ehlotyeni